Microfluidic fabric-based electrochemical device for detection of clinical analytes in physiological fluids

dc.contributor.authorMalon Marugan, Radha Swathe Priya
dc.date.accessioned2023-05-13T23:40:04Z
dc.date.available2023-05-13T23:40:04Z
dc.date.issued2014
dc.descriptionThesis (Ph.D (Biomedical Engineering))
dc.description.abstractIn recent years, inexpensive alternative materials (paper, yarn/thread and fabric) have been proposed for the construction of new generation of point-of-care (POC) microfluidic diagnostic devices. The purpose of this study is to investigate the integration of electrochemical detection in fabric-based microfluidic device for quantitative measurement of biomarkers in physiological fluids. The device was fabricated using two methods, template for patterning the electrodes and wax-patterning for creating the hydrophilic/hydrophobic contrast. The electrodes incorporated within the fabricated device were evaluated using cyclic voltammetry. The feasability of the device to determine clinical analytes such as glucose, lactate and ascorbic acid (AA) in control serum, saliva and artificial urine samples, respectively was demonstrated using chronoamperometry at the optimal detection potential (-0.2 V vs. Ag/AgCl for glucose and lactate; 0.28 V vs. Ag/AgCl for AA). The levels of the analytes measured were within the margin of error of the actual concentrations. The sensitivity of the device for the determination of glucose, lactate and AA were 0.294 ± 0.082, 0.3169 ± 0.099 and 0.4202 ± 0.229 |iA/mM, respectively, which are within the physiological range (2 to 25, 0.1 to 5 and 0.5 to 10 mM, respectively) of these analytes. The influence of mechanical stress towards the morphology and electrochemical behaviour were examined for both microfluidic fabric-based electrochemical device (^FED) and microfluidic paper-based electrochemical device (^PED). The results implied that the proposed |iFED was more durable under mechanical stress (sensitivity drop of ~ 21.6%) in comparison to the |iPED (sensitivity drop of ~ 48.6%). A three dimensional (3D) |iFED prototype for sample collection and continuous assessment (t = 170 min) of dynamic electrochemical measurement was also developed and evaluated. The |iFED provided an efficient sample delivery towards the reaction chamber, allowing dynamic electrochemical measurement in real-time without interruption unlike the |iPED. This study shows the potential of the proposed |iFED as a novel microfluidic sensing platform for a variety of assays that require simplicity, low-cost, portability, flexibility and continuous real-time monitoring
dc.description.sponsorshipFaculty of Biosciences and Medical Engineering
dc.identifier.urihttp://openscience.utm.my/handle/123456789/381
dc.language.isoen
dc.publisherUniversiti Teknologi Malaysia
dc.subjectBiosciences and medical engineering
dc.titleMicrofluidic fabric-based electrochemical device for detection of clinical analytes in physiological fluids
dc.typeThesis
dc.typeDataset
Files
Original bundle
Now showing 1 - 4 of 4
Loading...
Thumbnail Image
Name:
A_Radha Swathe.pdf
Size:
7.36 MB
Format:
Adobe Portable Document Format
Description:
The expected values for the human control serum samples (Level I and II)
Loading...
Thumbnail Image
Name:
C_Radha Swathe.pdf
Size:
7.36 MB
Format:
Adobe Portable Document Format
Description:
Photographs of the fabrication procedure of wax impregnated papers and scouring treatment of cotton fabric substrate
Loading...
Thumbnail Image
Name:
D_Radha Swathe.pdf
Size:
7.36 MB
Format:
Adobe Portable Document Format
Description:
The chronoamperometric response for the calibration of lactate using the C-PB/LOx electrodes of the lactate FED
Loading...
Thumbnail Image
Name:
E_Radha Swathe.pdf
Size:
7.36 MB
Format:
Adobe Portable Document Format
Description:
The CV, effect of applied potential and S/B ratios of the C-PB/GOx electrodes on the glucose µPED as obtained in the absence (0.1 M PBS) and presence of H2O2 (50 mM glucose)
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: